Magnit maydon kuchlanganligining sirkulyatsiyasi

Amperning to‘la tok qonunini yopiq kontur bo‘ylab o‘rganuvchi virtual laboratoriya

Tok kuchi I 5.00 A
Amper konturi radiusi R 10.0 cm
Tokning markazdan masofasi a 0.0 cm
Konturdagi H 7.96 A/m
∮H·dl 5.00 A
Kontur ichidagi tok Iich = 5.00 A
AMPER SIRKULYATSIYA QONUNI — VIRTUAL LABORATORIYA TOK KONTUR ICHIDA
YOPIQ AMPER KONTURI VA TOKLI O‘TKAZGICH x y L — yopiq Amper konturi I ⊙ a = 0.0 cm R = 10.0 cm P H dl ∮ H · dl = Iich SIRKULYATSIYA O‘LCHAGICHI YOPIQ KONTUR BO‘YLAB 5.00 A JORIY PARAMETRLAR I = 5.00 A R = 10.0 cm a = 0.0 cm H = 7.96 A/m Iich = 5.00 A Amper qonuni ∮H·dl = I

Virtual laboratoriya boshqaruvi

Tok kuchi I 5.00 A
Amper konturining radiusi R 10.0 cm
Tokli o‘tkazgichning markazdan siljishi a 0.0 cm
Kuzatish nuqtasi P burchagi φ

Magnit maydon kuchlanganligi sirkulyatsiyasining fizik mazmuni

L H · dl = Iich
L Hτ dl = Iich
Markaziy to‘g‘ri tok uchun: H = I/(2πR)
H · 2πR = I
Muhim: sirkulyatsiya qiymatini kontur ichida joylashgan toklar aniqlaydi. Tokli o‘tkazgich kontur tashqarisida qolsa, bu tokning yopiq kontur bo‘ylab magnit maydon sirkulyatsiyasiga algebraik hissasi nol bo‘ladi.
Tokli o‘tkazgich yopiq Amper konturining ichida joylashgan. Shu sababli kontur bo‘ylab H vektorining sirkulyatsiyasi tok kuchiga teng.